2007 Audi A4
Mileage
149,910
Service Date
2/18/2021
Services Performed
- Lubricate and check chassis. Change oil and oil filter. Check air filter and breather filter. Check all fluid levels and tire pressures. Preform basic safety inspection. Road test vehicle.
- Rotated and balanced tires, checked the brakes, checked the suspension components, checked the drivetrain, torque the wheels by manufacture specs.
- Technician checked the engine light scanned the PCM and found code P2070, P2006, P2007 Intake manifold flap stuck close. P2404 EVAP leak detection pump sense circuit implausible. Checked the intake manifold runner system and found the system works fine. Checked the intake vacuum to it and found there is no vacuum, checked and found the vacuum hose is broken to the main vacuum canister. Replaced the hose, clear the codes, test drive the car and no engine light came back and the system works fine.
- WINDOW REGULATOR – Removed & Replaced – Sedan Front Left
Juan O. gave our service a 5 star review on 2/18/2021